Sonic Horn Installation for ID Fan at Cement Plant
Application
Industry: Cement
Process: Preheater ESP
Location: ID Fan
Country: Binh Phuoc, Vietnam
Problem
The plant had been cleaning the ID fan in every major planned shutdown, but emergency shutdown still occurred due to dust accumulation on ID fan impeller that caused over vibration only after a month in operation. Due to this problem, the plant had to decrease its kiln capacity in order to keep the ID fan running within the acceptable vibration values.
Solution
Installing a Sonic Horn on the ID fan had been recommended for the plant to address the problem. Sonic Horn is a proven technology that prevents dust accumulation in many applications. It creates mechanical vibration using the sound energy generated from the diaphragm to dislodge dust.
Benefit
With the installation of Sonic Horn, the results are satisfactory that the plant manages to maintain the vibration values of the ID fan at minimum.

Direction of Sonic Horn to ID fan impeller

Piping and installation of Sonic Horn’s accessories

Mounting tube installed on ID fan body

Sonic Horn installed on mounting tube

Vibration values after installation of Sonic Horn